Your system will function fantastic, provided that the layer of rigid foam along with your roof sheathing has an R-value of not less than R-20. Should you be employing XPS, you will need no less than 4 inches of froth. Should you be applying polyisocyanurate, you would like at least three inches of foam.

Whilst vented roof assemblies are designed to dry to the exterior, unvented roof assemblies are meant to dry to the inside. That’s why an unvented roof assembly really should in no way include inside polyethylene.

4. After getting R-20 or R-twenty five of rigid foam along with your sheathing, it is possible to securely insulate down below your sheathing with Pretty much almost any insulation you need to use to deliver your insulation as much as minimum code necessities.

As an example that a particular making practice results in a 20% failure charge. That follow could well be thoroughly unacceptable to builders, who don't desire callbacks or headaches. But that apply would still cause eighty% of consumers getting pleased.

Chuck- Google "reclaimed foam." There are a number of sellers of reclaimed foam in MA. You will help save a bundle and aid the planet in addition.

This is a code violation to setup an air-permeable insulation like fiberglass batts amongst unvented rafters. It is also a foul strategy, simply because moisture can accumulate on your own roof sheathing if you are attempting this technique, and you will end up having sheathing rot.

Back again to the vent concept. I really Believe venting a roof that is definitely airsealed in the inside perfectly and created with no vent chutes is probably the best way to Establish cathedral ceilings.

This roof assembly appears to be like very cathedral but if i realize appropriately its not vented in any respect, but has generous earlier mentioned sheathing see this foam. Is that this regarded a vapour Harmless assembly considering this informative article says "Put in rigid foam insulation previously mentioned the roof sheathing and air-permeable insulation concerning the rafters.

Many thanks for your reaction Martin. Would you still be satisfied to implement that unvented system for any renovation problem where by There may be non-breathable membrane (eg bitumous 'felt') earlier mentioned reliable board sheathing?

The R price of your cut'n'cobbled foam + exterior foam must be at the least 40% of the center-cavity R price for dew issue Manage for the foam/fiber boundary in zone 5. If It is really developing a little shy of that before including the exterior foam it's not a major deal while in the short term, but if it'll be 5-ten years in advance of re-roofing to lift the foam-R to above 40% of the full It can be really worth applying vapor barrier latex primer about the gypsum board, or a sensible vapor retarder in between the gypsum board & fiberglass.

My belief is that the steep side of a mansard roof is often a roof. This can be especially true if the outside in the sloped assembly is finished with roofing.

The system is to install it (from the inside of your house) regarding the exact time the drywall is set up. I'll instruct my crew to be certain there aren't any air pockets from the purlin cavities & no air move in the latter.

Throughout the summer time, roof ventilation will not noticeably reduce the temperature of asphalt shingles or other sorts of roofing.

We've made a decision to insulate on the outside with the roof sheathing many of the way across each side of your additional hints gable roof, in an effort to match up the roof lines.